Optima Edge

Download Product PDF

MCS 524 SQ



Enquire

MCS 524 SQ
Optic Diameter 5.25 mm
Overall Diameter 12.00 mm
Optic Design Aberration Neutral, Negative Aspheric Biconvex
Haptic Design “C” Design with Step Vault
PCO Protection 360° perfect Square edge around the optic edge
Suggested A. Constant 118.4
Refractive Index 1.4915
Nominal A 118.4
Haigis a0 0.779
Haigis a1 0.400
Haigis a2 0.100
HofferQ pACD 5.01
Holl. 1 Const sf 1.23
SRK/T A 118.2
SRK II A 118.4

MCS 553SQ



Enquire

MCS 553SQ
Optic Diameter 5.50 mm
Overall Diameter 12.50 mm
Optic Design Aberration Neutral, Negative Aspheric Biconvex
Haptic Design “C” Design with Step Vault
PCO Protection 360° perfect Square edge around the optic edge
Suggested A. Constant 118.4
Refractive Index 1.4915
Nominal A 118.4
Haigis a0 0.779
Haigis a1 0.400
Haigis a2 0.100
HofferQ pACD 5.01
Holl. 1 Const sf 1.23
SRK/T A 118.2
SRK II A 118.4

MCS 603SQ



Enquire

MCS 603SQ
Optic Diameter 6.00 mm
Overall Diameter 12.50 mm
Optic Design Aberration Neutral, Negative Aspheric Biconvex with 2 Holes
Haptic Design “C” Design with Step Vault
PCO Protection 360° perfect Square edge around the optic edge
Suggested A. Constant 118.4
Refractive Index 1.4915
Nominal A 118.2
Haigis a0 0.673
Haigis a1 0.400
Haigis a2 0.100
HofferQ pACD 4.91
Holl. 1 Const sf 1.12
SRK/T A 118.04
SRK II A 118.2

MCS 602SQ



Enquire

MCS 602SQ
Optic Diameter 6.00 mm
Overall Diameter 13.00 mm
Optic Design Aberration Neutral, Negative Aspheric Biconvex with 2 Holes
Haptic Design “C” Design with Step Vault
PCO Protection 360° perfect Square edge around the optic edge
Suggested A. Constant 118.2
Refractive Index 1.4915
Nominal A 118.2
Haigis a0 0.673
Haigis a1 0.400
Haigis a2 0.100
HofferQ pACD 4.91
Holl. 1 Const sf 1.12
SRK/T A 118.04
SRK II A 118.2
  • CQ PMMA- Bio-compatibility material with UV filter ensuring adepuqte UV protection.
  • single piece Chamber with posterior side Square edge rounded Anterior Edge
  • Aberration neutral aspheric lenses are designed with uniform power from center to edge and reduced glare & glistening
  • 360° Sharp Edge around the whole outline of the optic reduces the cell adhesion for highest possible PCO prevention.
  • The Haptics design with step vault ensures, better contact with the capsular bag and better centration post operatively.
  • Power Available : -10.0 D to +40.0 D
    (+10.0 D to +30.0 D in 0.5 D teps -10.0 D to +9.0 and +31.0 to +40.0 D in 1.0 D steps)
  • Optics are Yag Laser compatible
  • Sterilized by Ethylene Oxide
Scroll to Top