Astig Toric – VUE

Download Product PDF
Brand Astigmatic – VUE
Material Toric biocompatible Flexible
Single Pack, Automatic UV Filter
Model MOT-415 MOT-416
Optic Size 6.00 mm 6.00 mm
Haptic Size 12.50 mm 13.00 mm
Haptic Design Single Haptic
Optic Biconvex Posterior Toric Aspheric Surface
Edge Design Continuous 360 degree Square Edge
AC Depth 5.25 mm
Incision Size 2.2 mm / 2.4 mm
Diopter Range Toric Cylinder power 1.50 D to 6.00 D in 0.75 increments
Spherical power 10.00 D to 25.00 D in 0.50 increments
Refractive Index 1.460
A constant Ultrasound Optical Biometry
Nominal A A
Height -0 118.4
Height -0.1 0.400
Height -0.2 0.100
Hoff/Q pACD 5.02
Holl. 1 Const @ 1.47
SRK/T 118.4 119.7
SRK II 118.6 119.9
IOL Model In IOL Plane
MOT-415T1 (1.50) 1.50
MOT-415T2 (2.25) 2.25
MOT-415T3 (3.00) 3.00
MOT-415T4 (3.75) 3.75
MOT-415T5 (4.50) 4.50
MOT-415T6 (5.25) 5.25
MOT-415T7 (6.00) 6.00
Brand Astigmatic
Material Toric Hydrophobic Foldable
Single Piece, Automatic UV Filter
Model AIT-455 AIT-459
Optic Size 6.00 mm 6.00 mm
Haptic Size 13.50 mm 13.50 mm
Haptic Design Single Haptic Plate Haptic
Optic Biconvex, Convex, Posterior Toric Aspheric Surface
Edge Design Continuous 360 degree Square edge
AC Depth 5.00 mm
Incision Size 2.4 mm
Diopter Range Toric Cylinder power 1.50 D to 6.00 D in 0.75 increments
Spherical power -10.00 D to 25.00 D in 0.50 increments
Refractive Index 1.460
A constant Ultrasound Optical Biometry
Haigis a0 5.34
Haigis a1 0.400
Haigis a2 0.100
Hoff/Q pACD 4.80
Holl. Const @ 1.02
SRK/T A 117.8
SRK II A 118.0
Model In IOL Plane
MOT-415T1 (1.50) 1.50
MOT-415T2 (2.25) 2.25
MOT-415T3 (3.00) 3.00
MOT-415T4 (3.75) 3.75
MOT-415T5 (4.50) 4.50
MOT-415T6 (5.25) 5.25
MOT-415T7 (6.00) 6.00

This is custom heading element

Sharp Vision

 

Leave a Legacy of outstanding vision

As the quantity of toric procedures increases, trust your legacy to an IOL that delivers exceptional visual quality.

The Astig Toric IOL adheres to a high standard of optical excellence so you can give each patient, the sharp, brilliant vision they never thought possible.

Excellent Astigmatism Correction

In a clinical study evaluating the Astig Toric IOLs for astigmatism correction in cataract patients, 94% of eyes achieved < 0.5 D of residual refractive cylinder, and 98% of eyes achieved. **Modular Transfer Function (MTF) is a measure of the amount of contrast transferred by the optics in a visual system. The higher the MTF value, the more contrast transferred to the image resulting in higher image contrast.

 

Superior Image Contrast

 

Enhanced Functionality

Leave a Legacy of Living

Your patients are far from ready to throw in the towel. They’ve got places to go and sights to see and they’ll see them all through the IOL you choose. Give them a lens designed to function in real-world conditions, such as in low light or without glasses, so they can experience each day with outstanding clarity.

Long-Term Sustainability

Leave a Lasting Legacy

What good is a lens if it’s not built to last? Make your legacy one you continually be proud of with an IOL that delivers exceptional stability, high patient satisfaction and stunning visual performance.

OUTSTANDING POSTIOP ROTATIONAL STABILITY

Stability is especially important for those with astigmatism. Toric IOLs demonstrate an excellent 2.74O mean axis change between the baseline and six months.

Rotation of the Astig Toric 1-Piece IOL away from its intended axis can reduce its astigmatic correction. Misalignment greater than 300 may increase

WARNING

Postoperative refractive cylinder. If necessary, lens repositioning should occur as early as possible prior to lens encapsulation.

Scroll to Top